Purifier Logic+ Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. All models are NSF-Listed.

These biological safety cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.

During operation, room air is drawn into the inlet grill. The air in the plenum beneath the work surface is a mixture of unfiltered room air and air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area. The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter. 

  • Widths - 4' and 6'
  • Voltages - 115V or 230V
  • Electronically Commutated Motor (ECM)
  • Constant Airflow Profile (CAP) airflow monitoring system
  • Intrinsically safe negative pressure design
  • Air-Wave™ Entry System
  • Contain-Air™ Negative Pressure Channel
  • Supply and exhaust 99.99% efficient HEPA filters. 99.999% efficient ULPA filters available
  • Interior-mounted, line-of-sight color LCD with MyLogic OS. Displays filter life, status messages for alarm conditions and alerts. 8 languages available
  • Bright, 90-150 foot-candle, glare-free LED lighting located outside the contaminated work area
  • Fully-closing, clear 1/4" tempered safety glass sash
  • Curved stainless steel inlet grille with Reserve-Air Secondary Airflow Slots
  • Two electrical duplex receptacles. Flush-mounted-stainless steel with dampened hinges. Single outlets on 230V models. One outlet on each side, with ground fault interruption (115V)
  • Smart-Start™ System user-programmable startup & shut down
  • Night-Smart™ System reduces blower speed when sash is closed
  • Leak-tight stainless-steel interior & powder-coated steel exterior
  • Removable towel catch located under work surface
  • Code-activated electronic security lock
  • 22.6" (57 cm) max. sash opening & 27.0" (69 cm) viewing height
  • 10° Angled sash with counterbalanced, easy lift mechanism
  • ADA-Compliant touchpad control on right side post
  • Noise level <63 dBA
  • Heat load 990 BTU/hour (4' models)
  • Removable, seamless type 304 stainless steel, dished work surface with lift out knobs
  • Nominal inflow velocity of 105 fpm (0.5 m/sec)
  • Nominal downflow velocity of 55 fpm (0.3 m/sec)
  • Approximately 70% air recirculation
  • Overall depth x height: 31.2" x 61.7" (79.2 x 156.7 cm)
  • 10' (3 m) power cord with plug
  • Built-in timer and digital clock
  • Five-year warranty
  • Models can be customized with options such as UV Light, Valves (Air, Vacuum, etc.), Cord, Cable & Tubing Portal
  • Compliance - 
    • ETL listed
    • NSF International listed
    • ADA-compliant (height of controls and receptacles)
    • CE Conformity marking (230V models)
    • ISO 5 conditions per ISO 14644-1 and 2
  • Sold Individually


Multiple Options

The CentriVap® DNA Centrifugal Concentrator speeds evaporation of solvents from DNA or other small samples. The bench-top cabinet houses the concentrator, rotor, diaphragm vacuum pump, two glass traps and all connecting tubing. No additional components are required to begin processing. A Quick-Start button starts the rotor, heater, timers and vacuum pump. Three separate Quick-Start buttons store one user-set program each. Temperature, heat time and run time can be set with just the touch of a few buttons. The user may also alter temperature and times while the program is in progress. Heat and run times are set separately so that heat may be programmed to shut down sooner than the run, which protects heat-sensitive samples from excessive heat exposure after the solvent has evaporated.

The Quick-Stop system ensures that within seconds of run time expiring (or if the RUN/STOP button is pressed), the vacuum pump stops, the valve opens to bleed air into the chamber, and the rotor stops. A DNA Rotor is included, which accommodates up to 60 (1.5mL or 2.0mL) or 72 (0.5mL) microcentrifuge tubes. Two 177mL glass traps protect the vacuum pump and the environment. One is located between the chamber and the vacuum pump. The other is located at the pump™s exhaust outlet. A large chamber holds more samples for greater throughput. Thick-wall aluminum chamber is epoxy-coated for corrosion resistance (Teflon-coated chambers are also available). Optional CentriZap Strobe Light, which plugs into the back of the CentriVap, enables the user to view samples while the rotor is spinning. A Glass Lid is also available.

52- and 24-Place Rotor
¢ Holds 36 to 52 Tubes, 12 to 13mm diameter
¢ Holds 18 to 24 Tubes, 16 to 17mm diameter

40- and 108-Place Rotor
¢ Holds 40 x 1.5 or 2.0mL Microcentrifuge Tubes
¢ Holds 16 to 100 Tubes, 12 to 13mm diameter

32- and 12-Place Rotor
¢ Holds 32 x 1.5 or 2.0mL Microcentrifuge Tubes
¢ Holds 12 x 28mm diameter Tubes

Microtiter Plate Rotor
¢ Holds 4 Each Standard 96-Well Plates
¢ Holds 2 Each Deep Well 96-Well Plates

DNA, 72- and 60-Place Rotor (Included with Unit)
¢ Holds 72 x 0.5mL Microcentrifuge Tubes
¢ Holds 60 x 1.5 or 2.0mL Microcentrifuge Tubes



Multiple Options

Specially designed for sensitive and demanding liquid handling applications, these filter tips eliminate false signals and contamination from aerosols and offer improved accuracy. Protect your samples and your pipettor.

Offering a large variety of universal pipet tips for your research needs. Most tips fit a variety of pipettors. For specific fit for your pipettor please call Customer Service at [phone].


Multiple Options

Specially designed for sensitive and demanding liquid handling applications, these filter tips eliminate false signals and contamination from aerosols and offer improved accuracy. Protect your samples and your pipettor.

Offering a large variety of universal pipet tips for your research needs. Most tips fit a variety of pipettors. For specific fit for your pipettor please call Customer Service at [phone].




# P10-600

Pipet Tips Natural 1-300ul Universal, Bu lk 1000/pk, 10pk/cs


# P23-206

Pipet Tips, Aerosol-Free, 1-20ul, Non- S terile, 1000/pk


# P13-350L

Pipet Tips Beveled and Graduated Rack 1- 200ul Natural 96 Tip Rack 10rack/pk


# T90-130

Test Tube Disposable Sterile 17 x 100 Po lypropylene w/o Cap 125/bag 1000/cs.


# T90-125

Test Tube Disposable Sterile 17 x 100 Po lypropylene W/Cap 125/bg 1000/cs


# T90-124

Tubes Culture Sterile Disposable with Sn ap Cap 17x100mm PS 125/Tray 1000/cs


# T90-107

Test Tube Disposable Sterile w/o cap 12X 75 Polystyrene 125/bag 1000/cs


# T90-104

Tube Culture 12x75 Sterile Polypropylene 125/Bag 1000/cs



# P23-217

Pipet Tips Aerosol-Free 1-950ul Natural Non-Sterile Bulk 1000/pk


# P23-120

Pipette Tips, 200ul, Aerosol-Free, 53510106 High Recovery, 96/rack, 10racks/pk, 10pk/cs


# P23-119

Pipet Tips, Aerosol-Free, 1-1000ul, Ster ile, 96/rack, 6racks/pk


# P23-111

Aerosol-Free Pipet Tips 1-160ul Sterile 96/rack 960/pk 10PK/CS


# P10-655

Pipet Tip Natural 1-300ul Universal Rack ed 96/rack 960/pk


# P10-130

Universal Tip Bevel 200ul Yellow NS 192/hinged rack 9600/case


# P10-128

Pipet Tip, Univ, Natural, Grad, 192/Stac k Rack, 5 rack/pk, 10pk/cs


# C90-210-A

Acid Resistant Refrigerated CentriVap Centrifugal Vacuum Concentrator