Beckman Biomek P30 XL Robotic Filter Tip for Hamilton, 384-head, Clear, Pre-Sterile, 45無 - 3840/Pack, 5 Packs/Case

Item #P21-328   Mfg #FXF-384-XL-RS

Automation Tips for Beckman Platforms

Experience the difference that Biotix proprietary technologies can bring to your high throughput screening assays. Biotix 384 automation tips features include: FlexFit, Delta Filter, X-Resin, Blade and Statix.

Download Biotix BA-0051-3FC Specification Sheet

QUALITY TESTING

RNase/Dnase

Products are washed in distilled water and concentrated via centrifugation. Samples are added to previously established nucleic acid standards, incubated for 1 hour at 37 C, and tested on 2% gel using electrophoresis. Products must show no degradation of standards to pass.

Nucleic Acid

Products are washed in distilled water and concentrated via centrifugation. Then, samples are added to protocol specified PCR reactions and thermal cycled for 50 cycles. A 2% agarose gel electrophoresis is used to examine experimental samples, positive controls and negative controls. To pass, product samples must show no DNA amplification. Test sensitivity is 10 ng.

Endotoxin/Pyrogen

Products are tested for endotoxins by using the Limulus Amebocyte Lysate (LAL) gel assay according to FDA guidelines. Test sensitivity is 0.06 EU/ml.

Trace Metal

Products are washed in distilled water. The sample is then tested using reflectometry using a single strip test for the following metals: Ca, Cu, Fe, K, Mg, Mn and Ni. Standard solutions are used as positive controls. A reader is used to detect metals to a sensitivity of 500 mg/L.

PCR Inhibitor

Products are tested via PCR amplification and gel electrophoresis analysis. Samples must show normal amplification to be considered free of PCR inhibitors

Sterililzation

Products are sterilized using electron beam irradiation

CV Test

Each lot of Biotix product is CV tested and the resulting CV is then printed on the pack label. The volume tested is equal to the maximum volume per tip size

TIR - Total Indicated Runout

Biotix pipette tips are tested to ensure that they meet the SBS standards. Individual products specify their compatibility with 96, 384 or 1536-well plates

PROPRIETARY TECHNOLOGIES

  • Statix - Static reduction and prevent technology (Patent Pending)
  • X-Resin - Proprietary resin, virgin polypropylene
  • Delta Filter - Color change filter (Patents Pending)
  • Blade - Minimal distal end orifice (Patents Pending) 

PIPETTOR COMPATIBILITY :

    • Beckman Biomek FX with 384 head
    • Beckman Biomek NX with 384 head
    • Beckman Multimek with 384 head

 

more
$2,195.00

Automation Tips for Beckman Platforms

Experience the difference that Biotix proprietary technologies can bring to your high throughput screening assays. Biotix 384 automation tips features include: FlexFit, Delta Filter, X-Resin, Blade and Statix.

Download Biotix BA-0051-3FC Specification Sheet

QUALITY TESTING

RNase/Dnase

Products are washed in distilled water and concentrated via centrifugation. Samples are added to previously established nucleic acid standards, incubated for 1 hour at 37 C, and tested on 2% gel using electrophoresis. Products must show no degradation of standards to pass.

Nucleic Acid

Products are washed in distilled water and concentrated via centrifugation. Then, samples are added to protocol specified PCR reactions and thermal cycled for 50 cycles. A 2% agarose gel electrophoresis is used to examine experimental samples, positive controls and negative controls. To pass, product samples must show no DNA amplification. Test sensitivity is 10 ng.

Endotoxin/Pyrogen

Products are tested for endotoxins by using the Limulus Amebocyte Lysate (LAL) gel assay according to FDA guidelines. Test sensitivity is 0.06 EU/ml.

Trace Metal

Products are washed in distilled water. The sample is then tested using reflectometry using a single strip test for the following metals: Ca, Cu, Fe, K, Mg, Mn and Ni. Standard solutions are used as positive controls. A reader is used to detect metals to a sensitivity of 500 mg/L.

PCR Inhibitor

Products are tested via PCR amplification and gel electrophoresis analysis. Samples must show normal amplification to be considered free of PCR inhibitors

Sterililzation

Products are sterilized using electron beam irradiation

CV Test

Each lot of Biotix product is CV tested and the resulting CV is then printed on the pack label. The volume tested is equal to the maximum volume per tip size

TIR - Total Indicated Runout

Biotix pipette tips are tested to ensure that they meet the SBS standards. Individual products specify their compatibility with 96, 384 or 1536-well plates

PROPRIETARY TECHNOLOGIES

  • Statix - Static reduction and prevent technology (Patent Pending)
  • X-Resin - Proprietary resin, virgin polypropylene
  • Delta Filter - Color change filter (Patents Pending)
  • Blade - Minimal distal end orifice (Patents Pending) 

PIPETTOR COMPATIBILITY :

    • Beckman Biomek FX with 384 head
    • Beckman Biomek NX with 384 head
    • Beckman Multimek with 384 head

 

  • Color:

    Clear

  • Compatible Model:

    Beckman

  • Capacity:

    P30

  • Filtered:

    Yes

  • Manufacturer:

    Biotix

  • Sterile:

    Yes